Chint Residual Current Operated Circuit Breaker NXBLE-63 2P C32A

Product description

 1745291591785.pngThe following is a detailed description of the **Chint Residual Current Operated Circuit Breaker NXBLE-63 2P C32A**, covering technical parameters, installation key points, certification information and procurement suggestions:

 I. Core Technical Parameters Chint NXC series small contactors

1. **Rated Current and Protection Characteristics**

   - **Rated Current (Iₙ)**: 32A, suitable for circuits with a load power ≤ 7.36kW (230V) or 21.12kW (380V).

   - **Residual Current Action Value (IΔn)**: By default **30mA** (in line with IEC 61008 standard), which can quickly detect and cut off the leakage current to prevent the risk of electric shock.Chint NXR series thermal overload relays price

   - **Tripping Curve**: Type C (5-10×Iₙ), suitable for resistive loads such as lighting and sockets; Type D (10-14×Iₙ) requires special customization (such as for motor loads).

   - **Breaking Capacity**: 6kA, which can safely cut off the short-circuit current.

2. **Electrical and Mechanical Characteristics*CHINT circuit breaker price

   - **Number of Poles**: 2P (controls both the live wire and the neutral wire simultaneously, and the neutral wire is only disconnected in case of a fault).

   - **Voltage Range**: 230V~ (single-phase) / 400V~ (three-phase), with a frequency of 50/60Hz.

   - **Ambient Temperature**: From -35°C to +70°C, humidity ≤ 90% (at 20°C), altitude ≤ 2000m.

   - **Dimensions**: Width 36mm (2 modules), height 85mm, depth 65mm, supporting installation on a 35mm standard rail.

3. **Certification and Compliance*CHINT surge protector price**

   - **Domestic Certifications**: CCC (China Compulsory Certification), CQC (China Quality Certification Center).

   - **International Certifications**: CE (European Union), TÜV (Germany), and SASO certification for the Middle East market is supported (contact the distributor to apply).

   - **Standards**: In compliance with GB/T 16917.1 and IEC 61008-1.

 II. Installation and Wiring GuidelinesSchneider Circuit Breakers

1. Preparation before Installation

- **Tools**: Screwdriver, wire stripper, torque wrench (a torque of 8-10N·m needs to be applied).

- **Materials**: Copper core wires below 6mm² (multi-strand flexible wires are recommended), and flame-retardant wire conduits.

- **Safety Measures**: Disconnect the main power supply and operate after confirming there is no voltage with a tester.

2. Installation StepsChint NXC series small contactors

1. **Fixing the Circuit Breaker**

   - Snap the circuit breaker onto the 35mm rail of the distribution box, ensuring that the clips on both sides are fully fastened to avoid loosening.

   - The spacing between adjacent circuit breakers should be ≥ 20mm to ensure heat dissipation.


2. **Wiring Requirements**

   - **Incoming Line Terminals**:

     - Connect the live wire (L) to the 1P terminal on the left side, and the neutral wire (N) to the N terminal on the right side.

     - Strip the wire about 10mm in length, insert it into the terminal and tighten the screw to ensure there is no looseness.

   - **Outgoing Line Terminals**:

     - Connect the live wire of the load to the 1P outgoing terminal, and the neutral wire to the N outgoing terminal.

     - In the case of a three-phase circuit, ensure that the neutral wire is connected synchronously with other phase wires.

3. **Residual Current Protection Test**

   - After the installation is completed, press the **Test Button (TEST)**, and the circuit breaker should trip immediately.

   - After restoring the power supply, test again to confirm the normal function.

3. Precautions

- **Neutral Wire Connection**: The neutral wire must be connected through the N terminal, and it is prohibited to disconnect or bypass it.

- **Load Matching**: Avoid overloading (long-term load ≤ 27A), otherwise it may lead to misoperation.

- **Environmental Requirements**: Keep away from high-temperature, humid or corrosive environments to avoid affecting performance.

 III. Application Scenarios and Selection Suggestions

1. **Typical Applications**

   - **Residential Power Distribution**: Socket circuits in wet areas such as kitchens and bathrooms, and high-power equipment such as electric water heaters and air conditioners.

   - **Commercial and Light Industry**: Lighting and socket systems in small offices and convenience stores.

   - **New Energy Field**: Protection of the AC side of photovoltaic inverters and energy storage systems (DC compatibility needs to be confirmed, and it is recommended to contact technical support).

2. **Selection Comparison**

CharacteristicsNXBLE-63 2P C32ASchneider C65ELM 2P C32AABB F202-C32
Residual Current30mA30mA30mA
Breaking Capacity6kA6kA6kA
Price (RMB)WA:0086-138112355435WA:0086-13811255435WA:0086-13811255435

IV. Procurement and After-sales Service

1. **Price and Bulk Purchase**

   - **Unit Price**: WA:0086-13811255435 yuan RMB (a 20% discount is available for bulk purchases of ≥ 50 units).

   - **Purchase Channels**:

     - **Authorized Distributor**: Such as Hebei China Electric CO., LTD (in the Middle East region, WhatsApp: 86-13811255435).

2. **Technical Support and Warranty**

   - **Warranty Period**: 18 months (excluding man-made damage).

   - **After-sales Consultation**:

     - Free on-site guidance can be applied for in case of bulk purchases (≥ 500 units).

     - Regional Sales Manager's Email: sales000888@gmail.com.

3. **Certification Documents**

   - CE, RoHS, SASO and other certification certificates can be provided (apply to the distributor).

   - The technical manual includes installation guidelines, tripping curves, etc., and can be downloaded from Chint's official website.

V. Fault Troubleshooting and Maintenance


1. **Common Problem Handling**

   - **Frequent Tripping**:

     - Check if the load is overloaded or if there is leakage in the circuit.

     - Confirm whether the neutral wire connection is firm to avoid poor contact.

   - **No Action**:

     - Check if the test button is normal or if the residual current module is damaged (it needs to be returned to the factory for repair).

   - **Contact Heating**:

     - Check if the wiring terminals are loose or if the load exceeds the rated current.

2. **Regular Maintenance**

   - Clean the dust in the arc extinguishing chamber every quarter and measure the contact resistance of the contacts (≤ 50mΩ).

   - Calibrate the tripping characteristics with a test bench every year (the action time should meet the standard).

VI. Accessories and Extended Functions

- **Optional Accessories**:

  - **Auxiliary Contacts (AX-X1)**: Used for remotely monitoring the status of the circuit breaker.

  - **Shunt Trip Device (SHT-X1)**: Trips by an external signal (such as a fire alarm system).

  - **Alarm Contacts (AL-X1)**: Sends out audible and visual alarms in case of a fault.

- **Customized Requirements**:

  - DC voltage compatibility (contact Chint's technical team).

  - IP55 protection level enclosure (suitable for outdoor or dusty environments).


VII. Safety Warnings

1. **Prohibited Operations**:

   - It is strictly prohibited to disassemble or modify the circuit breaker while it is live.

   - It is prohibited to mix the neutral wire with the ground wire, which may lead to equipment damage or electric shock.

2. **Emergency Situations**:

   - In case of a short circuit or leakage, cut off the main power supply immediately and have it repaired by a professional electrician.

For further technical support or customized solutions, please directly contact the regional manager of Chint Electric, Hebei China Electric.